Bug ID 1024553: GTM Pool member set to monitor type "none" results in big3d: timed out

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
13.1.4, 13.1.4.1, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2

Fixed In:
15.1.5, 14.1.4.5, 13.1.5

Opened: Jun 10, 2021

Severity: 3-Major

Symptoms

A pool member is marked down with a 'none' type monitor attached.

Impact

Setting a pool member to have "none" monitor should result in a blue "checking" status but it may mark the pool member as down/unavailable.

Conditions

-- GTM pool member with a 'none' monitor configured

Workaround

NA.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips