Bug ID 1026581: NETFLOW/IPFIX observationTimeMilliseconds Information Element value is not populated correctly.

Last Modified: Dec 18, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 14.1.4.6, 14.1.5, 14.1.5.1, 14.1.5.2, 14.1.5.3, 14.1.5.4, 14.1.5.6, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 15.1.10.5, 15.1.10.6, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2, 17.0.0, 17.0.0.1, 17.0.0.2

Opened: Jun 16, 2021

Severity: 3-Major

Symptoms

When logging Carrier Grade NAT Port Port Block Allocation (CGNAT PBA) events using NetFlow/IPFIX log destinations, if the AFM module is not enabled, the observationTimeMilliseconds Information Element value is incorrectly reported as zero in reported events.

Impact

CGNAT PBA events containing the observationTimeMilliseconds Information Element will report incorrect values for this field.

Conditions

Using CGNAT PBA, logging to a NetFlow/IPFIX log destination, and AFM is not enabled.

Workaround

1) Enable AFM module, or 2) Enable lsn-legacy-mode in the log profile

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips