Last Modified: May 29, 2024
Affected Product(s):
BIG-IQ AppIQ
Known Affected Versions:
8.0.0, 8.0.0.1
Fixed In:
8.1.0.1
Opened: Jul 04, 2021 Severity: 3-Major
BIG-IQ analytics become unresponsive and errors display in the /var/log/elasticsearch log.
Analytics are not report as expected.
BIG-IQ configured with Data Collection Devices (DCD)s.
Perform the following steps on each DCD: 1. Edit /var/config/appiq/agentmanager/config/application-bigiq.yml For"indexes-overflow-protection" change the "initial-delay" from 7200000 to 0. 2. Save the configuration. 3. Restart appiqagent to reload the configuration by typing: bigstart restart appiqagent
This issue is now fixed and analytics work as expected.