Last Modified: May 29, 2024
Affected Product(s):
BIG-IP ASM
Fixed In:
17.0.0, 16.1.2.2, 15.1.5.1
Opened: Aug 30, 2021 Severity: 3-Major
In the GUI under Security ›› Application Security : Audit : Reports, if you select "User-input parameters..." in the menu "Security Policy Audit Reports", then click on the parameter to retrieve the properties, you will see this error: " Could not retrieve parameter; Could not get the Parameter, No matching record was found."
A page error occurs.
1) Create a new parameter. 2) Customize or overwrite an existing ASM signature for the parameter in question. 3) Save and apply to the policy the new changes 4) Go to: Security ›› Application Security : Audit : Reports Report Type : User-input parameters with overridden attacks signatures (this also happens for other "User-input parameters...") Select the parameter to audit Error: "Could not retrieve parameter; Could not get the Parameter, No matching record was found."
1. Open in a separate tab the following screen: Security ›› Application Security : Parameters : Parameters List 2. Under "Parameter List" title, there is a filter dropdown with the "Parameter Contains" texting. 3. On the blank part (before "Go" button) type the name of the required parameter. 4. You will get the desired page with the desired parameter properties.