Bug ID 1050413: Drive model HGST HUS722T1TALA604 must be added to pendsect drives.xml

Last Modified: Feb 12, 2024

Affected Product(s):
BIG-IP All(all modules)

Known Affected Versions:
11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 14.1.4.6, 14.1.5, 14.1.5.1, 14.1.5.2, 14.1.5.3, 14.1.5.4, 14.1.5.6, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2

Fixed In:
17.0.0, 15.1.10

Opened: Sep 28, 2021

Severity: 4-Minor

Symptoms

When using the hard drive model HGST HUS722T1TALA604, the pendsect does not recognize the hard drive and skips during sector checks.

Impact

Warning messages like the following will be logged to /var/log/messages: -- warning pendsect[31898]: skipping drive -- Model: HDC WD1005FBYZ-01YCBB2 -- warning pendsect[31898]: No known drives detected for pending sector check. Exiting Pendsect can't properly check the hard drive.

Conditions

The issue occurs under the following conditions: -- Using a HGST HUS722T1TALA604 hard drive on a BIG-IP system. -- Pendsect runs a sector check.

Workaround

Give write permissions to modify files: chmod u+w /etc/pendsect/drives.xml Open the file and add the following at the end of the file, before default: <snip> <HUS722T1TA> <offset firmware="RAGNWA09">0</offset> <offset firmware="default">0</offset> <family> "HA210"</family> <wd_name>"Ultrastar"</wd_name> </HUS722T1TA> <DEFAULT> <firmware version="default"> <offset>0</offset> </firmware> <name> "UNKNOWN"</name> <family> "UNKNOWN"</family> <wd_name>"UNKNOWN"</wd_name> </DEFAULT> </model> </drives> Save and close the file. Remove write permissions so that no one accidentally modifies this file: chmod u-w /etc/pendsect/drives.xml Run the following command and check /var/log/messages to verify no errors are seen: /etc/cron.daily/pendsect

Fix Information

None