11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 14.1.4.6, 14.1.5, 14.1.5.1, 14.1.5.2, 14.1.5.3, 14.1.5.4, 14.1.5.6, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2, 16.1.4.3, 16.1.5, 16.1.5.1
Fixed In:
17.0.0, 15.1.10
Opened: Sep 28, 2021 Severity: 4-Minor
When using the hard drive model HGST HUS722T1TALA604, the pendsect does not recognize the hard drive and skips during sector checks.
Warning messages like the following will be logged to /var/log/messages: -- warning pendsect[31898]: skipping drive -- Model: HDC WD1005FBYZ-01YCBB2 -- warning pendsect[31898]: No known drives detected for pending sector check. Exiting Pendsect can't properly check the hard drive.
The issue occurs under the following conditions: -- Using a HGST HUS722T1TALA604 hard drive on a BIG-IP system. -- Pendsect runs a sector check.
Give write permissions to modify files: chmod u+w /etc/pendsect/drives.xml Open the file and add the following at the end of the file, before default: <snip> <HUS722T1TA> <offset firmware="RAGNWA09">0</offset> <offset firmware="default">0</offset> <family> "HA210"</family> <wd_name>"Ultrastar"</wd_name> </HUS722T1TA> <DEFAULT> <firmware version="default"> <offset>0</offset> </firmware> <name> "UNKNOWN"</name> <family> "UNKNOWN"</family> <wd_name>"UNKNOWN"</wd_name> </DEFAULT> </model> </drives> Save and close the file. Remove write permissions so that no one accidentally modifies this file: chmod u-w /etc/pendsect/drives.xml Run the following command and check /var/log/messages to verify no errors are seen: /etc/cron.daily/pendsect
None