Bug ID 1054497: Tmsh command "show sys fpga" does not report firmware for all blades.

Last Modified: Dec 18, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 15.1.10.5, 15.1.10.6, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2, 16.1.4.3, 16.1.5, 16.1.5.1

Opened: Oct 12, 2021

Severity: 4-Minor

Symptoms

After upgrading or forcing a reload of the configuration, the tmsh command "show sys fpga" does not report the firmware for all blades.

Impact

The tmsh command "show sys fpga" does not report firmware information for all blades.

Conditions

- Mutli-blade VIPRION or vCMP guest. - Upgrade or forced reload of the configuration

Workaround

Use the following command to restart chmand on the blade that is not reporting the firmware information: bigstart restart chmand

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips