Bug ID 1055785: SmartNIC 2.0: stats throughput logging is broken on Virtual Edition dashboard.

Last Modified: Dec 07, 2023

Affected Product(s):
BIG-IP AFM(all modules)

Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1

Fixed In:
15.1.5

Opened: Oct 19, 2021

Severity: 3-Major

Symptoms

When using a fastl4 acceleration profile on a virtual server, throughput on the dashboard shows a much lower number of packets than the same traffic with a non-accelerated profile.

Impact

Smartnic 2.0 stats throughput data is incorrect.

Conditions

A fastl4 profile is used on a virtual server when only using 1 virtual server.

Workaround

None

Fix Information

Set the snoop's TMM number to the correct TMID instead of the pde number.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips