Bug ID 1095185: Failed Configuration Load on Secondary Slot After Device Group Sync

Last Modified: Feb 07, 2024

Affected Product(s):
BIG-IP ASM(all modules)

Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 17.0.0, 17.0.0.1, 17.0.0.2

Fixed In:
17.1.0, 16.1.4, 15.1.9

Opened: Apr 06, 2022

Severity: 2-Critical

Symptoms

Configuration synchronization fails on secondary slots after the primary slot receives a full sync from a peer in a device group.

Impact

Incorrect enforcement on secondary slots.

Conditions

Bladed chassis devices are configured in an ASM enabled device group

Workaround

None

Fix Information

Synchronization to secondary slots is successful.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips