Bug ID 1115041: BIG-IP does not forward the response received after GOAWAY, to the client.

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 17.0.0, 17.0.0.1, 17.0.0.2

Fixed In:
17.1.0, 16.1.4, 15.1.9

Opened: Jun 15, 2022

Severity: 3-Major

Symptoms

After receiving a GOAWAY from the server followed by data on the same stream, the BIG-IP system does not forward that data to the client but rather sends RESET_STREAM.

Impact

The client does not get a proper response

Conditions

1. Configure an NGINX server to handle two streams per connection 2. Virtual server with http2 profile 3. Send more than two requests on the same connection

Workaround

None

Fix Information

The client should receive proper response.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips