Last Modified: Oct 09, 2024
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
15.1.8.2, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2, 16.1.4.3, 16.1.5, 16.1.5.1, 17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3
Fixed In:
17.1.1, 15.1.9
Opened: Sep 19, 2022 Severity: 3-Major
Following error message appears in the GUI: This device is not operational because the loaded configuration contained errors or unlicensed objects. Please adjust the configuration and/or the license, and re-license the device.
Failed to load the license on disabled slot from primary slot.
- The primary blade disabled manually using the following TMSH command: modify sys cluster default members { 1 { disabled } }
Execute the following command on disabled slot: rm /var/db/mcpdb.* bigstart restart mcpd Note: This causes a system to go offline while services restart. Traffic disrupted while services restart. or Execute command "reloadlic" which reloads the license into the current MCPD object.
None