Last Modified: May 29, 2024
Affected Product(s):
F5OS Velos
Fixed In:
F5OS-C 1.6.0
Opened: Sep 28, 2022 Severity: 2-Critical
Attempting to set the blade front panel ports into a 100:10/25G or 40:10/25G configuration will result in a non-functional data path. The blade may appear to be linked at the physical layer, but no traffic will pass through the blade until the front panel port speed configuration is the same for both ports (for example, 2x100g, 2x40G, 2x 4x10G).
No traffic will pass through the blade. Tenants will not deploy.
Setting a mixed speed configuration on the front panel ports (for example, one port at 100G and the other at 4x10G, or one port at 40G and the other at 4x10G).
If mixed front panel port speeds are required, update to the next version when it becomes available.
If mixed front panel port speeds are required, update to the next version when it becomes available.