Bug ID 1165973: Application error while using the CLI command "show components"

Last Modified: May 29, 2024

Affected Product(s):
F5OS None(all modules)

Known Affected Versions:
F5OS-A 1.3.0, F5OS-A 1.3.1, F5OS-A 1.3.2, F5OS-C 1.3.0, F5OS-C 1.3.1, F5OS-C 1.3.2, F5OS-C 1.5.0, F5OS-C 1.5.1

Fixed In:
F5OS-C 1.6.0, F5OS-A 1.5.0, F5OS-A 1.4.0

Opened: Sep 30, 2022

Severity: 3-Major

Symptoms

The user receives an error message using the CLI (show components -> Error: application error) when there is a faulty sensor in the hardware.

Impact

Application error seen in the ConfD CLI while trying to execute "show components". The webUI is affected as well.

Conditions

When the system has the faulty sensor.

Workaround

N/A

Fix Information

We have added a check at diag-agent to not throw the application error; it will show data for the healthy components.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips