Bug ID 1168309: Virtual Wire traffic over trunk interface sometimes fail in Tenant based platforms

Last Modified: Oct 04, 2024

Affected Product(s):
BIG-IP Velos(all modules)

Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2, 16.1.4.3, 16.1.5, 16.1.5.1

Fixed In:
17.1.0, 15.1.9

Opened: Oct 10, 2022

Severity: 4-Minor

Symptoms

Traffic does not flow through the virtual-wire trunk. Traffic through the interface is not impacted.

Impact

Traffic outage might occur.

Conditions

When there is an overlap between the DID values of the interface and trunk, virtual-wire traffic does not pass through the trunk.

Workaround

None

Fix Information

The conflict between Interface DID values and Trunk DID values are avoided, by marking whether the DID value belongs to a trunk or interface.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips