Last Modified: May 29, 2024
Affected Product(s):
F5OS (all modules)
Known Affected Versions:
F5OS-A 1.3.1, F5OS-A 1.3.2, F5OS-C 1.5.1
Fixed In:
F5OS-C 1.6.0, F5OS-A 1.4.0
Opened: Nov 08, 2022 Severity: 3-Major
If the system reboots without an ISO imported after bare metal install, it will try to set up the port 2000 registry as a mirror of itself, which is not correct and results in the registry being empty. Because of this, the tenants are not being deployed.
Tenants will not deploy.
In bare metal install ISO is not imported.
Import the version of the ISO that matches the version of the image used to perform the bare metal installation.
When patch release is being installed, the correct 'active version of services' is taken which makes the registry not empty. Hence the tenants will be deployed without any issue.