Bug ID 1217077: Race condition processing network failover heartbeats with timeout of 1 second

Last Modified: Apr 26, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2, 16.1.4.3, 17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3

Opened: Jan 06, 2023

Severity: 4-Minor

Symptoms

Unexpected failover or log messages similar to the following: sod[1234]: 010c0083:4: No failover status messages received for 1.100 seconds, from device bigip02(192.0.0.1) (unicast: -> 192.0.0.2)

Impact

A failover event could impact traffic flow.

Conditions

- HA configuration network failover configured - DB variable 'failover.nettimeoutsec' set to a value of 1 second.

Workaround

Following recommended practices of configuring network failover addresses using both the Management IP and Self IP addresses will reduce the chances of initiating a failover. Log messages may still be observed. Setting the DB variable 'failover.nettimeoutsec' to a value of 2 or greater should avoid the issue.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips