Bug ID 1286165: Ping failing after removing aggregate ID from interface and adding trunk VLANs in the same commit

Last Modified: Aug 01, 2024

Affected Product(s):
F5OS Velos(all modules)

Fixed In:
F5OS-A 1.7.0, F5OS-A 1.5.1

Opened: Apr 10, 2023

Severity: 2-Critical

Symptoms

Ping to self IP of tenant failing.

Impact

Ping to self IP of tenant will fail.

Conditions

This issue will be observed only when tried from F5OS ConfD CLI. Removing aggregate ID and assigning trunk VLANs to an interface in the same commit from ConfD CLI.

Workaround

From F5OS CLI 1)Remove aggregate ID from interface. 2)commit the changes. 3)Add trunk VLANs to interface and commit the changes. For example: 1)no interfaces interface 3.0 ethernet config aggregate-id 2)commit; top 3)interfaces interface 3.0 ethernet switched-vlan config trunk-vlans [ 3700 3800 3900 ] 4)commit

Fix Information

NA

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips