Bug ID 1289633: FIPS devices show incorrect vCPUs

Last Modified: Aug 01, 2024

Affected Product(s):
F5OS None(all modules)

Fixed In:
F5OS-A 1.7.0, F5OS-A 1.5.2

Opened: Apr 17, 2023

Severity: 3-Major

Symptoms

1. The Dashboard System Summary shows 36 vCPUs rather than the actual number of vCPUs available for Tenant Deployment. 2. The Add/Edit Tenant deployments screen allows selecting up to 36 vCPUs instead of the maximum vCPUs that the platform supports.

Impact

No functional impact.

Conditions

FIPS device.

Workaround

Users can view the correct value for total vCPUs for tenant deployment on the device from the CLI using the following command: "show cluster nodes node node-1 state node-info"

Fix Information

vCPUs information will show appropriately on the dashboard based on the platform support, and Add/Edit Tenant deployment screen will have vCPU options up to the maximum that the platform supports and not beyond that.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips