Bug ID 1291121: BIG-IP tenants on F5OS r5000, r10000, and r12000 platforms don't pass traffic properly while in forced offline state

Last Modified: Dec 18, 2024

Affected Product(s):
BIG-IP F5OS, TMOS(all modules)

Known Affected Versions:
15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 15.1.10.5, 15.1.10.6, 17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3, 17.1.1.4, 17.1.2

Opened: Apr 19, 2023

Severity: 3-Major

Symptoms

Monitors may flap. Connections generated from the tenant will succeed and others will fail. The ConfigSync status for a tenant that is forced offline will report disconnected.

Impact

Traffic to/from the tenant does not work properly when the tenant is forced offline, although the behavior can be intermittent.

Conditions

BIG-IP tenant running on r5000, r10000, and r12000-series appliances. Note: F5OS tenants on VELOS chassis will not pass traffic while the tenant is forced offline, but that behavior is not tracked by this ID. For more information, see K15122: Overview of the Force Offline option for devices and traffic groups (https://my.f5.com/manage/s/article/K15122)

Workaround

None

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips