Bug ID 1307385: When blade replacement happens, signature config is lost in bigip.conf when IM is loading on a new blade

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP AFM(all modules)

Known Affected Versions:
14.1.4.5, 14.1.4.6, 14.1.5, 14.1.5.1, 14.1.5.2, 14.1.5.3, 14.1.5.4, 14.1.5.6

Opened: Jun 15, 2023

Severity: 3-Major

Symptoms

The bigip.conf file differs before and after blade replacement

Impact

The bigip.conf does not list all the signatures added in the IM which is active

Conditions

It happens when one of the blades is replaced

Workaround

1) Try the command "tmsh save sys config" 2) If step 1 does not resolve the issue then try reloading the IM (Move to Factory Defaults IM and load the IM again). Then the bigip.conf will be updated with all the signatures supported by that IM)

Fix Information

None

Behavior Change

Guides & references