Last Modified: Mar 12, 2025
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 15.1.10.5, 15.1.10.6, 17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3, 17.1.1.4, 17.1.2, 17.1.2.1
Opened: Sep 22, 2023 Severity: 3-Major
This only fails if the config on the tenant has not been saved on first boot or after a virtual wire has been added to the tenant config on F5OS.
After running tmsh load sys config, all or some of the VLANs for the virtual wire object are no longer in the running config. The vlan-group created for the virtual wire object is longer in the running config
1. Create a virtual wire object on F5OS 2. Create a F5OS BIG-IP tenant adding the the virtual wire object to the tenants config 3. Deploy the tenant 4. Run tmsh load sys config on the tenant
Save the config on the tenant after the first boot and on any addition/removal of virtual wire objects.
None