Bug ID 1361021: The management interface media on a BIG-IP Tenant on F5OS systems does not match the chassis

Last Modified: Aug 10, 2024

Affected Product(s):
BIG-IP F5OS, F5OS-A, F5OS-C, TMOS(all modules)

Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3

Opened: Sep 28, 2023

Severity: 5-Cosmetic

Symptoms

The management interface media on a BIG-IP tenant running on F5OS systems does not match the media/speed of the management interface on the system controllers. Running 'tmsh show net interface' reports the media of the management interfaces (i.e. 'mgmt' or '1/mgmt') as "100TX-FD".

Impact

The media is reported as "100TX-FD".

Conditions

BIG-IP tenant running on F5OS systems (rSeries or VELOS).

Workaround

Ignore the speed reported for the tenant's management interface(s), and instead, look at the speed of the management interfaces as reported in F5OS. While running confd, run the following command to see the correct media settings: VELOS: show interfaces interface 1/mgmt0 rSeries: show interfaces interface mgmt

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips