Last Modified: Oct 09, 2024
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 15.1.10.5, 17.1.1, 17.1.1.1
Fixed In:
17.1.1.2
Opened: Dec 01, 2023 Severity: 2-Critical
The chassis manager daemon (chmand) is wedged and does not fully start causing MCPD and cluster to never start.
The slot does not come online and stays inoperative.
This issue is seen when IPv6 alternate addresses to the cluster members are added and rebooted to a slot.
None
Using the copy of a variable for a bad iterator has fixed the issue.