Bug ID 1462409: PVA dedicated mode in F5OS tenants needs eviction disabled

Last Modified: Dec 31, 2024

Affected Product(s):
BIG-IP F5OS-A, LTM, Velos(all modules)

Known Affected Versions:
17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3, 17.1.1.4

Fixed In:
17.1.2

Opened: Dec 15, 2023

Severity: 3-Major

Symptoms

PVA dedicated mode will not work in F5OS tenants until pva flow eviction is disabled.

Impact

PVA connections may not all be accelerated. They will not be using the neuron engine.

Conditions

Low latency license, dedicated mode enabled in the fastl4 profile.

Workaround

tmsh modify ltm profile fastl4 myfastl4 pva-flow-evict disabled

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips