Bug ID 1962785: Monitors of type snmp_link can fail

Last Modified: Oct 15, 2025

Affected Product(s):
BIG-IP GTM, Link Controller(all modules)

Fixed In:
17.5.1.2, 17.1.3

Opened: May 29, 2025

Severity: 3-Major

Symptoms

Monitors of type snmp_link can fail as they may not be added to the active probe list.

Impact

Availability status may be shown in red.

Conditions

Use of monitor type snmp_link.

Workaround

None

Fix Information

Removed the condition check for adding Monitors to the active probe list.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips