Last Modified: Oct 21, 2026
Affected Product(s):
F5OS Velos
Known Affected Versions:
F5OS-C 1.8.2, F5OS-C 1.8.2-HR1, F5OS-C 1.8.2-HR2, F5OS-C 1.8.2-HR3
Fixed In:
F5OS v2.0.0
Opened: Sep 08, 2025 Severity: 3-Major
Chassis system controller "show lacp interfaces interface" show interfaces present on the standby controller when the standby is not present and/or powered-off.
LAG member mismatch may cause blade control-plane connectivity problems.
LAG interface state is not always properly propagated when a controller transitions to 'standby'. If that standby controller becomes 'active' prior to update, the data persists.
Reboot the active controller.
Operational data is properly synchronized across active/standby transitions.