Bug ID 645615: zxfrd may fail and restart after multiple failovers between blades in a chassis.

Last Modified: Oct 16, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
11.5.4, 11.5.5, 11.5.6, 11.6.0, 11.6.1, 11.6.2, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1

Fixed In:
13.1.0.2, 13.1.0, 12.1.3.1, 11.6.3, 11.5.7

Opened: Feb 16, 2017

Severity: 2-Critical

Related Article: K70543226

Symptoms

zxfrd may fail and restart after multiple failovers between blades in a single chassis.

Impact

zxfrd will create a core file and restart, picking up where it left off.

Conditions

DNS Express must be configured in a multi-blade chassis. If a blade transitions from active to backup to active states and the DNS Express (tmmdns.bin) database has been re-created while the blade was in backup status, zxfrd may fail when attempting to reference old data.

Workaround

None.

Fix Information

The cause of the failure is now addressed.

Behavior Change