Last Modified: Apr 28, 2025
Affected Product(s):
BIG-IP Install/Upgrade
Known Affected Versions:
12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8
Fixed In:
14.0.0, 13.1.1, 12.1.3.5
Opened: Mar 27, 2017 Severity: 4-Minor
Chassis Variant number is not specified when checking the log file /var/log/ltm, for example: #grep queryFDD /var/log/ltm ...debug chmand[12982]: 012a0007:7: queryFDD returned 1 items for: update|F100|||NONE|NONE|NONE|0x0 This should contain the Variant number 400-0028-04, as follows: ...debug chmand[32663]: 012a0007:7: queryFDD returned 1 items for: update|F100|400-0028-04||NONE|NONE|NONE|0x0
This has no impact, since there are no Variants currently defined for the C2200/C2400 chassis.
-- B2100/B2150/B2200 blade in C2200/C2400 chassis. -- Checking for the Chassis Variant number.
There is no workaround at this time.
Chassis Variant number is printed out as expected in the log file.