Bug ID 663946: The vCMP host may drop IPv4 DNS requests as DoS IPv6 atomic fragments

Last Modified: Dec 18, 2024

Affected Product(s):
BIG-IP AFM, vCMP(all modules)

Known Affected Versions:
11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 14.1.4.6, 14.1.5, 14.1.5.1, 14.1.5.2, 14.1.5.3, 14.1.5.4, 14.1.5.6, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 15.1.10.5, 15.1.10.6

Fixed In:
16.0.0

Opened: May 10, 2017

Severity: 3-Major

Related Article: K92111062

Symptoms

On a vCMP platform with host and guest using different BIG-IP versions, when DNS is under load greater than the AFM-configured rate limit, certain IPv4 packets are categorized as IPv6 atomic fragments and may be dropped due to rate limits.

Impact

May result in lower than expected DNS load test results.

Conditions

-- vCMP platform with host and guest using different BIG-IP versions. -- AFM enabled. -- DNS load greater than AFM-configured rate limit for IPv6 atomic fragments (default 10 KB) at DoS device.

Workaround

You can use any of the following workarounds: -- Disable AFM. -- Increase detection limit for IPv6 atomic fragments under AFM. -- Disable hardware offload with sys db Dos.VcmpHWdos. Note: For AFM HW DoS protection, the host and vCMP guest must be the same version, disable hardware DoS checking on the vCMP guest to prevent this issue. To do so, set sys db dos.forceswdos to 'true'.

Fix Information

The hardware DoS offload is by default disabled on vCMP guests. To enable hardware DoS offload, within the guest, set sys db dos.vcmphwdos to true.

Behavior Change

A new sys db Dos.VcmpHWdos is added to BIG-IP. By default the value is false. Under the default value hw dos is disabled on VCMP platform. Users will need to enable the sys db within the guest to access the hw dos functionality.