Bug ID 694696: On multiblade Viprion, creating a new traffic-group causes the device to go Offline

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7

Fixed In:
14.0.0, 13.1.0.8, 12.1.3.2

Opened: Nov 15, 2017

Severity: 3-Major

Symptoms

All devices in the failover device group will go offline, resulting in traffic disruption and possible failovers.

Impact

Traffic to all other traffic-groups is disrupted for several seconds.

Conditions

When a new traffic-group is created on a multiblade Viprion system that is a member of a sync-failover device group.

Workaround

There is no workaround at this time.

Fix Information

Creating a new traffic-group does not disrupt existing traffic-groups.

Behavior Change