Bug ID 703959: Manual thresholds for DoS Protection Dynamic Signatures are not accepted via TMUI

Last Modified: Apr 17, 2024

Affected Product(s):
BIG-IP AFM(all modules)

Known Affected Versions:
13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4

Fixed In:
13.1.0.4

Opened: Jan 27, 2018

Severity: 3-Major

Symptoms

Manual thresholds for DoS Protection Dynamic Signatures are not accepted via TMUI. The 'Infinite' values for detection and mitigation are retained. No error message is returned.

Impact

The BIG-IP system Administrator is not aware that config change failed to be applied.

Conditions

Attempting to configure manual AFM detection and mitigation threshold for DoS Protection Dynamic Signatures using the Management GUI.

Workaround

Manual thresholds for Dynamic Signatures can be configured using TMSH.

Fix Information

You can now change manual detection and mitigation threshold via TMUI.

Behavior Change

Guides & references