Bug ID 707951: Stalled mirrored flows on HA next-active when OneConnect is used.

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 14.0.0, 14.0.0.1, 14.0.0.2

Fixed In:
14.1.0, 14.0.0.3, 13.1.1.2, 12.1.3.6

Opened: Feb 26, 2018

Severity: 3-Major

Symptoms

-- 'tmctl -d blade tmm/umem_usage_stat | grep xdata' may show increased memory usage. -- 'tmsh show sys connect' shows idle flows.

Impact

- Some flows are mirrored incorrectly. - Stalled flows may occupy a lot of memory.

Conditions

- OneConnect profile is configured. - High availability (HA) mirroring is enabled.

Workaround

Disable OneConnect.

Fix Information

Stalled mirrored flows no longer appear when OneConnect is used.

Behavior Change

Guides & references