Last Modified: Apr 28, 2025
Affected Product(s):
BIG-IP Install/Upgrade
Known Affected Versions:
13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1
Fixed In:
14.1.0, 13.1.1.2
Opened: Apr 13, 2018 Severity: 3-Major
If you are doing platform-migrate from a hardware device to a Virtual Edition (VE) guest, and the UCS that came from the hardware device has a QinQ VLAN configuration, then the upgrade will fail.
The UCS load will fail and generate an error: 01071bd8:3: The tag-mode for requested member <VLAN name> has to be 'none' on platforms that do not support QinQ. Unexpected Error: Loading configuration process failed.
-- VLAN with a QinQ configuration exists on the hardware configuration. -- UCS file is saved on the hardware device. -- UCS is copied to a VE guest. -- Attempt to load the configuration using the following command: load sys ucs <UCS filename> no-license platform-migrate.
None.
The configuration now loads successfully, disables QinQ on the associated VLAN, and warns that this action was automatically taken.