Bug ID 720104: BIG-IP i2800/i2600 650W AC PSU has marketing name missing under 'show sys hardware'

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 14.0.0, 14.0.0.1, 14.0.0.2

Fixed In:
14.1.0, 14.0.0.3, 13.1.1, 12.1.3.6

Opened: May 14, 2018

Severity: 3-Major

Symptoms

BIG-IP i2800/i2600 650W AC PSU is missing marketing name under 'show sys hardware' and displays 'unknown' when OID sysObjectID is queried.

Impact

System reports an empty marketing name when queried. Platform with 650W AC PSU not identified using tmsh command or snmpwalk.

Conditions

-- Execute 'tmsh show sys hardware'. -- Query for OID sysObjectID using snmpwalk. -- Using BIG-IP i2800/i2600 platforms.

Workaround

There is no workaround at this time.

Fix Information

Added new SNMP OID for BIG-IP i2800/i2600 650W AC PSU.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips