Last Modified: May 29, 2024
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 14.1.4.6, 14.1.5, 14.1.5.1, 14.1.5.2, 14.1.5.3, 14.1.5.4, 14.1.5.6, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4
Fixed In:
14.0.0
Opened: May 16, 2018 Severity: 2-Critical
Some iAppLX package files on primary blade do not exist on secondary blades.
When a failover occurs to a blade with an incomplete iAppLX package, parts of the iAppLX GUI may not work.
After installing an iAppLX package on a multi-blade chassis the package files are synced to other blades. This process is not instantaneous and may take several minutes. During this time if the same iAppLX package is upgraded, not all of the files will be synced across blades, and an incomplete iAppLX package will exist on secondary blades.
To trigger a resync of files from primary to secondary blades run the following command: bigstart restart csyncd
The system now syncs files from primary to secondary blades in this scenario.