Last Modified: Jul 13, 2024
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1
Fixed In:
15.0.0, 14.1.0.2
Opened: May 23, 2018 Severity: 3-Major
If the level of ltm monitor inheritance (defaults-from) is too large, i.e 9. then mcpd will fail to send sod a heartbeat within the heartbeat timeout; therefore sod will restart mcpd.
mcpd is restarted which will cause services to failover.
LTM monitors that have 9 levels of inheritance i.e. mon1 defaults from mon2, which defaults from mon3, which defaults from mon4 ... to mon10
Rework the ltm monitors so that the level of inheritance is less than 9.
None