Last Modified: May 29, 2024
Affected Product(s):
BIG-IP Install/Upgrade, TMOS
Known Affected Versions:
14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4
Fixed In:
15.1.0, 14.1.2.1
Opened: Jun 29, 2018 Severity: 3-Major
When running the Configuration Utility in the GUI, after clicking Next on the License screen, the GUI reports an error and you are unable to proceed: Cannot find disk information.
You are unable to proceed through the configuration utility.
The conditions that trigger this are unknown; in one scenario, it was observed after running 'tmsh load sys config default', suspending the BIG-IP Virtual Edition (VE) guest, and then restarting it and running the Configuration Utility.
If this occurs, reboot the device, and the error will fix itself.
None