Bug ID 753805: BIG-IP system failed to advertise virtual address even after the virtual address was in Available state.

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3

Fixed In:
15.0.0, 14.1.3.1, 13.1.3.4, 12.1.5.3

Opened: Dec 20, 2018

Severity: 3-Major

Symptoms

After failover, a longer time than expected for the virtual server to become available.

Impact

Virtual server takes longer than expected to become available.

Conditions

-- There is a configuration difference in the pool members before and after the configuration synchronization. -- Probe status is also different.

Workaround

Run full sync (force-full-load-push) from the active BIG-IP system to solve this issue.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips