Last Modified: May 29, 2024
Affected Product(s):
BIG-IP All
Known Affected Versions:
14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5
Fixed In:
15.0.0, 14.1.0.6
Opened: Feb 15, 2019 Severity: 3-Major
BIG-IP Virtual Edition (VE) with ixlv devices (Intel X710/XL710/XXV710 family) might not reliably pass traffic after a hard boot of the host on which it runs. The tmm log contains messages similar to the following: ixlv[0:8.0]: Error: AQ returned error -1 to request 10! ixlv[0:8.0]: Error: Error -1 waiting for PF to complete operation 4 ixlv[0:8.0]: Error: WARNING: Error adding VF mac filter! ixlv[0:8.0]: Error: WARNING: Device may not receive traffic! The host's kernel log might contain messages similar to the following: i40e 0000:06:00.0: VF is not trusted, switch the VF to trusted to add more functionality
IPv6 and other network traffic may be handled unreliably.
-- BIG-IP VE with one or more virtual functions that utilize the ixlv driver within tmm. -- Hard reboot the host and observe traffic. Note: This issue might be dependent upon the version of the PF driver in the host, and has been observed with at least 2.1.4 and 2.4.10, but this list is incomplete.
Reboot the guest. This problem has been observed only on the very first boot after a hard boot of the host.
None