Bug ID 759564: GUI not available after upgrade

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 16.0.0, 16.0.0.1

Fixed In:
16.1.0, 16.0.1, 15.1.1, 14.1.2.8

Opened: Feb 25, 2019

Severity: 3-Major

Symptoms

After installing over the top of a previous version, the Management GUI is inaccessible while SSH access works. You may see one or more of the following conditions Shell prompt may show logger[1234]: Re-starting named bigstart restart httpd fails bigstart start httpd fails

Impact

Corrupt install

Conditions

Installation over a previously used Boot Volume

Workaround

Boot back to previous boot volume and then delete the boot volume containing the failed install.

Fix Information

None

Behavior Change

Guides & references