Bug ID 761345: Additional config-sync may be required after blob compilation on a HA setup in manual config-sync mode

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP AFM(all modules)

Known Affected Versions:
13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2

Fixed In:
15.1.0, 14.1.2.3, 13.1.3.2

Opened: Mar 15, 2019

Severity: 3-Major

Symptoms

When manual config-sync mode is enabled for a HA setup, additional config-sync may be required after firewall blob compilation.

Impact

Additional config-sync may be required after compilation completion. A warning may be given: "There is a possible change conflict between <device1> and <device2>.", and full sync may be forced.

Conditions

Firewall rule configuration modified on a high availability (HA) setup with manual config-sync mode enabled.

Workaround

Enable auto config-sync instead of manual config-sync.

Fix Information

Additional config-sync is not required in these conditions.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips