Last Modified: May 29, 2024
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4
Fixed In:
15.1.0, 14.1.2.8
Opened: May 23, 2019 Severity: 3-Major
Changing parameters in a Web Acceleration profile does not change the behavior of virtual servers already using the profile.
The changes are saved correctly and are visible in the Web UI and tmsh; however, virtual servers already using the profile are not affected by the changes. This may result in some confusion and in the BIG-IP Administrator being unable to apply their desired changes.
This issue is encountered after changing the settings of a Web Acceleration profile already in use by one or more virtual servers.
After modifying the profile, remove the profile from all virtual servers and then re-add it.
None