Bug ID 794285: BIG-IQ reading AFM configuration fails with status 400

Last Modified: Jul 12, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6

Fixed In:
15.1.0, 14.1.2

Opened: Jun 16, 2019

Severity: 1-Blocking

Related Article: K36191493

Symptoms

When the BIG-IQ tries to read the AFM configuration, using REST, the operations fails with status 400, if AFM is provisioned but the Protocol Inspection module is not licensed.

Impact

The operations fails with status 400. BIG-IQ cannot read AFM configuration if Protocol Inspection module is not licensed.

Conditions

-- AFM provisioned on BIG-IP system. -- Protocol Inspection module is not licensed.

Workaround

License Protocol Inspection.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips