Bug ID 798105: Node Connection Limit Not Honored

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP All(all modules)

Known Affected Versions:
14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2

Fixed In:
15.1.0, 15.0.1.4, 14.1.2.1

Opened: Jun 25, 2019

Severity: 3-Major

Symptoms

Connection limits on nodes are not honored.

Impact

More traffic will pass to the node than the limit is supposed to allow.

Conditions

A node with connection limits set.

Workaround

Modify the node's limit after the node is created and it will start honoring the limit.

Fix Information

The node's limit is now honored.

Behavior Change

Guides & references