Last Modified: May 29, 2024
Affected Product(s):
BIG-IP APM
Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4
Fixed In:
16.0.0, 15.1.4.1
Opened: Aug 22, 2019 Severity: 2-Critical
SSO setting for Portal Access (PA) resource assigned to any webtop section cannot be updated due to the following error: No such atomic attribute:name in class:webtop_section_webtop_section_resource Configuration with such a resource cannot be transferred to another BIG-IP system due to the same error.
Configuration cannot be updated or transferred.
BIG-IP system configuration with the following objects: -- SSO configuration (any type). -- PA resource with resource item. -- The webtop section with the PA resource. -- Full webtop. -- Per-session access policy with resource assignment agent which assigns webtop, webtop section, and PA resource.
Delete webtop sections from the configuration and re-create them after transfer / upgrade / update process.
Now APM configuration with Portal Access resources in webtop sections can be transferred or upgraded.