Last Modified: May 29, 2024
Affected Product(s):
BIG-IP Install/Upgrade, TMOS
Known Affected Versions:
14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3
Fixed In:
15.1.0, 15.0.1.4, 14.1.2.3
Opened: Aug 23, 2019 Severity: 2-Critical
On a chassis system where the active/primary blade is running version 14.1.0 or later and a new blade is inserted that has version 14.0.0 or lower, the secondary blades fail to receive the updated images and the installation stalls. The primary blade reports 'Waiting for product image' when running the tmsh show sys software status command.
Newly inserted blade does not synchronize volumes with the primary blade and cannot be used. The tmsh show sys software status command reports that one or more blades are in 'waiting for product image' status indefinitely.
Primary blade running version 14.1.0 or above. Secondary running an earlier version is inserted.
Ensure all blades are running the same version. This can be accomplished manually by running the following command at the command prompt (this example is for new blade inserted at slot #3): scp /shared/images/* slot3:/shared/images
None