Bug ID 841277: C4800 LCD fails to load after annunciator hot-swap

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP All(all modules)

Known Affected Versions:
11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1

Fixed In:
16.0.0, 15.1.4, 14.1.4.3

Opened: Oct 20, 2019

Severity: 3-Major

Symptoms

After following F5-recommended procedures for hot-swapping the left annunciator card on a C4800 chassis and replacing the top bezel, the LCD screen fails to load.

Impact

-- Status light on the top bezel turns amber. -- LCD becomes unresponsive, and continuously displays 'F5 Networks Loading...'.

Conditions

- C4800 chassis with 2 annunciator cards. - Hot-swap the left annunciator card and replace the top bezel.

Workaround

1. Run the command: tmsh modify sys db platform.chassis.lcd value disable 2. Wait 10 seconds. 3. Run the command: tmsh modify sys db platform.chassis.lcd value enable. This forces the LCD to sync back up with the VIPRION system and returns it to normal operation. The top bezel status light should turn green.

Fix Information

The LCD now automatically reloads once a functioning annunciator card is inserted into the left slot and the top bezel is replaced. It may take up to 10 seconds for the LCD to return to normal functionality.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips