Bug ID 886045: Multi-NIC instances fail to come up when trying to use memory-mapped virtio device

Last Modified: Apr 24, 2024

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2, 16.1.4.3

Opened: Feb 28, 2020

Severity: 2-Critical

Symptoms

Multi-NIC instances fail to come up while using memory-mapped virtio device. Running the command 'lspci -s <pci-id> -vv' results in the 'region' field reporting 'Memory at xxxxx'.

Impact

The BIG-IP system fails to attach to the underlying virtio devices.

Conditions

TMM crashes as soon as the BIG-IP system tries to come up.

Workaround

Switch to the sock driver by overriding tmm_init.tcl. For instructions on how to enable the sock driver, see the workaround in K74921042: BIG-IP VE may fail to process traffic after upgrading the VMware ESXi 6.7 host to Update 2 (or later), available at https://support.f5.com/csp/article/K74921042.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips