Last Modified: May 29, 2024
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 14.1.4.6, 14.1.5, 14.1.5.1, 14.1.5.2, 14.1.5.3, 14.1.5.4, 14.1.5.6, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1
Fixed In:
16.0.0, 15.1.3
Opened: Apr 06, 2020 Severity: 3-Major
Handling of duplicate internal connections can tear down and clean up the newest connection. Instead it should always remove the oldest.
The cleanup of previous connections may incorrectly tear down the new connection. Error messages are reported in the log when this happens, for example: Duplicate connections between BCM56XXD1 and stpd7749-2. Closing the new one.
When internal connections are re-established.
None.
The system now always removes the oldest connection.