Bug ID 920149: Live Update default factory file for Server Technologies cannot be reinstalled

Last Modified: Feb 07, 2024

Affected Product(s):
BIG-IP ASM(all modules)

Known Affected Versions:
14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2, 16.1.0

Fixed In:
17.0.0, 16.1.1, 15.1.4.1, 14.1.4.4

Opened: Jun 23, 2020

Severity: 3-Major

Symptoms

Live Update default factory file for Server Technologies cannot be reinstalled once it is no longer the currently installed update file.

Impact

Live Update default factory file for Server Technologies cannot be reinstalled.

Conditions

This occurs: -- Once another update file for Server Technologies has been installed (most likely, a newer file). -- If the device has been upgraded from a prior release such that the currently installed Server Technologies file is from the previous release, and is not the default factory file for the current release.

Workaround

None.

Fix Information

None

Behavior Change

Guides & references