IKE-SAs are deleted on standby BIG-IP systems after a failover.
Some of the IKE-SAs are missing on the standby device. When a failover happens, IPsec traffic will be dropped for those missing SAs.
-- High availability (HA) environment -- Dead-peer detection (DPD) / liveness checks are enabled -- An HA failover occurs This is a timing issue and can occur intermittently during a normal failover.
Set IKE DPD interval time to ZERO (i.e., disable).
When the BIG-IP system is in standby mode, the system no longer retries sending IKE/IPSEC control messages, which prevents this issue from occurring.